Nubira CDX Wagon L4-2.0L DOHC D-TEC MFI (2000)
Generator: Service and Repair
Disassembly and Assembly
Disassembly
1. Remove the generator.
2. Mark a match line that cannot easily be removed on the end frame to make assembly easier.
3. Pry off the plastic cover to expose the stator connections.
NOTE: If the stator connections are not welded, melt the lead, Avoid excessive heating, as it can damage the diodes in the rectifier bridge.
4. Remove the stator connections from the rectifier bridge terminals by cuffing the wires.