1500 4x4 Pickup V8-360 5.9L Magnum (1996)
Alternator Lamp/Indicator: Description and Operation
CIRCUIT OPERATION
Circuit F14 supplies power for the generator lamp. The lamp illuminates when the Powertrain Control Module (PCM) provides ground for the
lamp on circuit G12. Circuit G12 connects to cavity C16 of the PCM.