dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Neutral Safety Switch|Locations|Page 5342 > < Neutral Safety Switch|Locations|Page 5340
Page 1
background image

Neutral Safety Switch: Testing and Inspection

-

In the START position, the ignition switch connects circuit A1 from the power distribution center (PDC) to circuit A41. A 40 amp fuse in cavity 3
of the PDC protects circuits A1 and A41.

-

The Park/Neutral position switch and backup lamp switch are molded together.

Neutral Safety Switch|Locations|Page 5342 > < Neutral Safety Switch|Locations|Page 5340