dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Oxygen Sensor|Testing and Inspection > < Diagram Information and Instructions|Page 1690
Page 1
background image

Oxygen Sensor: Description and Operation

O2 Sensor Cutaway View (Typical)

LOCATION

 

The heated oxygen sensors are located in each exhaust manifold in front of the catalytic converters.

PURPOSE

This vehicle uses two oxygen sensors. The Powertrain Control Module (PCM) uses these signals to fine tune air/fuel mixture for each cylinder
bank. This is done by varying injector pulse width (on time).

OPERATION

The oxygen sensor is a voltage generating device. A voltage signal (0-1 volt) is generated by comparing the difference in oxygen content between
the exhaust gases and outside air. The higher the difference (rich mixture, low exhaust oxygen content) the higher the voltage generated by the
oxygen sensor. Smaller differences (lean mixture, high exhaust oxygen content) result in a lower voltage being generated. 

On this engine, the left O2 sensor monitors odd numbered cylinders (1-3-5-7). Based on input from this sensor injection is adjusted on the left
bank of the engine. The right O2 sensor monitors even numbered cylinders (2-4-6-8). Based on input from this sensor injection is adjusted on the
right bank of the engine.

The oxygen sensor has a heating element that maintains proper oxygen sensor operating temperature at all times. This process allows the vehicle to
enter closed loop at an earlier time and to remain in closed loop during the remainder of the operating cycle. The oxygen sensor heating element
receives voltage from the fuel pump relay.

During CLOSED LOOP operation, the PCM monitors the signals it receives from the oxygen sensor, and other sensors, and uses these signals to
adjust the injector pulse width according to the current driving condition. 

During OPEN LOOP operation, the PCM ignores the oxygen sensor's signals, and other sensor's signals, and adjusts injector pulse widths
according to preprogrammed specifications in the PCM.

Oxygen Sensor|Testing and Inspection > < Diagram Information and Instructions|Page 1690