dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Recall - Crankcase Ventilation Orifice|Page 3213 > < Recall - Crankcase Ventilation Orifice
Page 2
background image

1.

Locate and inspect the crankcase ventilation (CCV) system fittings in the left and right valve covers (Figure 1).

^

If the GRAY CCV fitting is in the RIGHT valve cover, no further action is necessary.

^

If the GRAY CCV fitting is in the LEFT valve cover, continue with Step 2.

2.

Disconnect the CCV vacuum tubes from the CCV fittings and remove both fittings from the valve covers.

3.

Install the CCV fittings in the opposite valve cover from which they were removed.

IMPORTANT:

The fitting with an orifice is GRAY and it must be installed in the right valve cover (passenger side). The fitting without an orifice is BLACK and it
must be installed in the left valve cover (driver side).

4.

Connect the CCV vacuum tubing to both fittings.

Completion Reporting and Reimbursement

Claims for vehicles which have been serviced must be submitted on the DIAL System.

Claims submitted will be used by Chrysler to record recall service completions and provide dealer payments.

Use the following labor operation number and time allowance:

Inspect and/or relocate CCV orifice

Labor Operation Number

Time Allowance    

25736182

0.2 hours

Note

See the Warranty Administration Manual, Recall Claim Processing Section for complete recall claim processing instructions.

Parts Return
Not applicable.

Vehicle Not Available
If a vehicle is not available for service for a known reason, let us know by filling out the pre-addressed Vehicle Disposition Form portion of the Owner
Notification Form or describe the reason on a postcard and mail to:

Chrysler Corporation
CIMS 482-00-85

Recall - Crankcase Ventilation Orifice|Page 3213 > < Recall - Crankcase Ventilation Orifice