Ammeter Gauge: Testing and Inspection
Conventional Ammeter

Fig. 1 Conventional type ammeter (typical)

    A conventional ammeter must be connected between the battery and alternator in order to indicate current flow. This type ammeter consists of a frame
to which a permanent magnet is attached. The frame also supports an armature and pointer assembly. Current in this system flows from the alternator
through the ammeter, then to the battery or from the battery through the ammeter into the vehicle electrical system, depending on vehicle operating
conditions.
    When no current flows through the ammeter, the magnet holds the pointer armature so that the pointer stands at the center of the dial. When current
passes in either direction through the ammeter, the resulting magnetic field attracts the armature away from the effect of the permanent magnet, thus
giving a reading proportional to the strength of the current flowing.

TROUBLESHOOTING
    When the ammeter apparently fails to register correctly, there may be trouble in the wiring which connects the ammeter to the alternator and battery or
in the alternator or battery itself.
    To check the connections, first tighten the two terminal posts on the back of the ammeter. Then, following each wire from the ammeter, tighten all
connections on the ignition switch, battery and alternator. Chafed, burned or broken insulation can be found by following each ammeter wire from end to
end.
    All wires with chafed, burned or broken insulation should be repaired or replaced. After this is done, and all connections are tightened, connect the
battery cable and turn on the ignition switch. The needle should point slightly to the discharge ( - ) side.
    Start the engine and speed it up a little above idling speed. The needle should then move to the charge side (+), and its movement should be smooth.
    If the pointer does not behave correctly, the ammeter itself is out of order and a new one should be installed.