dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Voltage Regulator > < Bosch Alternators|Page 3750
Page 2
background image

Fig. 8 Charging circuit resistance test connections. 1984---85

1984---85

1.

Disconnect ground cable from battery and the "Bat" lead from alternator output terminal.

2.

Complete test connections as shown.

3.

Connect battery ground cable, then start engine and operate at idle.

4.

Adjust engine speed and carbon pile rheostat to obtain 20 amps in the circuit and observe voltmeter reading, which should not exceed .5 volt.

5.

If a higher voltage drop is indicated, inspect, clean and tighten all connections in the circuit. A voltage drop test at each connection can be
performed to isolate the problem.

Voltage Regulator > < Bosch Alternators|Page 3750