dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Fuel Injector Cleaning Procedure|Page 1691 > < Fuel System Controls|Page 1688
Page 1
background image

Fuel Injector: Service and Repair
Fuel Injector Cleaning Procedure

PROCEDURE:

1.

Fuel system pressure must be released prior to service.  See: Fuel Filter/Fuel Pressure Release/Service and Repair

2.

Disconnect the fuel supply line from the inlet side of the throttle body.

3.

Attach the fuel supply line to the return line.

4.

Plug the fuel return fitting, or connect to tester/cleaner depending on configuration.

5.

Connect the fuel supply hose from the tester/cleaner to the fuel supply manifold.

6.

Turn the tester/cleaner ON.  (Tester/cleaner should run 10 minutes.)

7.

START the engine and check the fuel lines for leakage.  If there is any sign of leakage, turn the vehicle and the tester/cleaner OFF and repair the
location where fuel is leaking.  Then return to Step 6.

8.

When the engine speed has stabilized, set the idle speed at 2000 rpm.  Run the remainder of the 10 minute cycle to eliminate all the air in the fuel
supply hose and fuel rail.

9.

Turn ignition switch OFF and disconnect power lines.

10.

Disconnect cleaner supply hose from the fuel supply manifold.

11.

Connect vehicle fuel lines.  START engine and check for leaks.  

 

Fuel Injector Cleaning Procedure|Page 1691 > < Fuel System Controls|Page 1688