dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

PCM - Excessive Crank Time/Start Die Out/Weak Run Up|Page 3118 > < PCM - Excessive Crank Time/Start Die Out/Weak Run Up
Page 2
background image

1

CH7035

General Purpose Interface Bus Cable (GPIB)

1

CH7000/7001

J1962 Cable

1

CH7010

J1962 MMC Cable

1

04669020

Label - Authorized Software Update

1

04275086

Label - Authorized Modification

NOTE

THE MDS AND DRB III(R) ARE REQUIRED TO PERFORM THIS REPAIR AND THE SYSTEM MUST BE OPERATING WITH RELEASE
21 OR HIGHER AND TIL CD RELEASE 1156 OR HIGHER MUST BE INSTALLED.

POLICY: Reimbursable within the provisions of the warranty. 

TIME ALLOWANCE:

Labor Operation No:

08-19-40-92

0.5 Hrs.

FAILURE CODE: FM - Flash Module

Repair Procedures

This bulletin involves selectively erasing and reprogramming the Powertrain Control Module (PCM) with new software (calibration changes).

1.

Connect the MDS (Mopar Diagnostic System) and DRB III(R) (Scan Tool) to the vehicle and power them up.

2.

Use the arrow keys and select # 2 MDS DIAGNOSTICS on the DRB III(R) MAIN MENU Screen.

3.

Use the arrow keys and select DIAGNOSTIC MENU on the MDS, then press NEXT MENU.

4.

Use the arrow keys and select VEHICLE CONTROLLER PROGRAMMING on the MDS, then press NEXT MENU.

5.

Use the arrow keys and select PROGRAMMING OF ALL OTHER CONTROLLERS USING MDS & DRB III(R) on the MDS, then press NEXT
MENU.

6.

Follow the steps presented on the MDS and DRB III(R) which will allow the DRB III(R) to obtain the current part number of the PCM.

7.

The MDS will display the part number of the PCM on the vehicle and the appropriate replacement part number, then press NEXT MENU to begin
programming.

If the PCM on the vehicle has already been updated or programmed, a NO UPDATES AVAILABLE message will be displayed. Check the part
number of the PCM on the vehicle and compare it to the part number displayed. If the PCM has already been updated, then another condition
exists that will require further diagnosis and repair.

8.

The MDS and DRB III(R) will prompt for any operator action needed during the remainder of the programming process.

NOTE

THE FOLLOWING STEPS ARE REQUIRED BY LAW.

9.

Type the necessary information on the "Authorized Software Update Label" p/n 04669020 (Figure 1). Attach the label to the PCM and cover the
label with the clear plastic overlay.

PCM - Excessive Crank Time/Start Die Out/Weak Run Up|Page 3118 > < PCM - Excessive Crank Time/Start Die Out/Weak Run Up