Avenger V6-2.5L VIN N (1998)
Shift Cable: Adjustments
1. Place selector lever in Neutral position.
2. Loosen transaxle control cable to manual control cable lever coupling nut to free cable and lever.
3. Place manual control lever in Neutral position.
4. Turn inhibitor switch body to align end of manual control lever to flange of inhibitor switch body, Fig.4.
5. Torque inhibitor switch mounting bolts to 7-8 ft. lbs.