dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Removal and Replacement|Page 6936 > < Removal and Replacement|Page 6934
Page 5
background image

2. Place the mounting bracket for the ICU (1) over the mounting screws (2) and hang the assembly in place. Tighten the two mounting screws (2) to

23 Nm (17 ft. lbs.).

CAUTION: Before installing the ABM harness connector on the ABM, be sure the seal is properly installed in the connector.

3. Insert the ABM wiring harness connector (2) into the socket of the ABM (1) and close the cover, locking the connector in place.

Removal and Replacement|Page 6936 > < Removal and Replacement|Page 6934