dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Dashboard / Instrument Panel > < Procedures|Page 12066
Page 2
background image

1. Position the Remote Compass Module (RCM) (2) onto the top of the Instrument Panel (IP) (1).
2. Connect the electrical connector.
3. Align the RCM mounting tab with the slot in the IP (4) and push forward to fully seat the RCM (2).
4. Install the RCM retaining screw (3).
5. Install the instrument panel top pad, See: Dashboard / Instrument Panel/Service and Repair/Instrument Panel Pad - Installation.
6. Connect the battery negative cable.
7. Perform the Compass Variance Adjustment, See: Procedures/Compass Variance Adjustment - EVIC.
8. Perform the Manual Compass Calibration, See: Procedures/Manual Compass Calibration - EVIC.
9. Verify proper compass operation.

Dashboard / Instrument Panel > < Procedures|Page 12066