Refrigerant Pressure Sensor / Switch: Service and Repair
Removal

REMOVAL

NOTE: It is not necessary to discharge the refrigerant system to replace the A/C pressure transducer.

NOTE: Typical A/C pressure transducer shown.

1. Disconnect and isolate the negative battery cable.
2. Disconnect the wire harness connector (1) from the A/C pressure transducer (2) on the A/C discharge line (3) located near the right side of the

radiator.

3. Remove the A/C pressure transducer from the A/C discharge line and remove and discard the O-ring seal (4).