dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Solenoid/Pressure Switch Assy|Page 6734 > < Solenoid/Pressure Switch Assy
Page 2
background image

switches is to help the PCM/TCM detect when clutch circuit hydraulic failures occur. The range for the pressure switch closing and opening points is
11-23 psi. Typically the switch opening point will be approximately one psi lower than the closing point.  For example, a switch may close at 18 psi and
open at 17 psi. The switches are continuously monitored by the PCM/TCM for the correct states (open or closed) in each gear as shown in the following
chart:

A Diagnostic Trouble Code (DTC) will set if the PCM/TCM senses any switch open or closed at the wrong time in a given gear.

The PCM/TCM also tests the 2/4 and OD pressure switches when they are normally off (OD and 2/4 are tested in 1st gear, OD in 2nd gear, and 2/4 in
3rd gear). The test simply verifies that they are operational, by looking for a closed state when the corresponding element is applied. Immediately after a
shift into 1st, 2nd, or 3rd gear with the engine speed above 1000 rpm, the PCM/TCM momentarily turns on element pressure to the 2/4 and/or OD clutch
circuits to identify that the appropriate switch has closed. If it doesn't close, it is tested again. If the switch fails to close the second time, the appropriate
Diagnostic Trouble Code (DTC) will set.

Solenoid/Pressure Switch Assy|Page 6734 > < Solenoid/Pressure Switch Assy