dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Water Pump > < Coolant Outlet Housing - Removal
Page 1
background image

Thermostat Housing: Service and Repair
Coolant Outlet Housing - Installation

2.7L

1. Clean sealing surfaces. Inspect gaskets for tears and cuts. Replace as necessary.
2. Install coolant outlet connector and tighten bolts to 12 Nm (105 in. lbs.).
3. Connect hoses at coolant outlet connector.
4. Connect engine coolant temperature sensor connector.
5. Install upper intake manifold See: Engine/Intake Manifold/Service and Repair/Removal and Replacement/Intake Manifold - Installation.
6. Fill cooling system See: Service and Repair 

Water Pump > < Coolant Outlet Housing - Removal