dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Fuel system - Engine Vapor Lock|Page 362 > < Fuel system - Engine Vapor Lock|Page 360
Page 13
background image

1.

Remove the fuel tank gauge unit from the fuel tank per service manual procedure and discard. Install the new seal and gauge/pump unit
from the applicable kit. Use extreme caution to protect the float and gauge assembly during installation into the fuel tank.

2.

With the fuel tank partially raised, connect the fuel tank vent hose, fuel return, and fuel supply hoses. Secure the hoses with the hose
clamps provided.

3.

Feed red and yellow molds of body wiring harness, PN 4362293, through slot in the crossmember. Remove existing screw for gauge unit
ground. Install eyelet terminal of harness, PN 4362293 (and ground eyelet terminal of 35 gallon tank gauge/pump unit), and torque ground
screw to 35 inch pounds.

CAUTION:

GROUND SCREW MUST BE TIGHTENED SECURELY TO OPERATE ELECTRIC PUMP AND GAUGE
UNIT.

FIGURE 3-A - 35 GALLON TANK

FIGURE 3-B - 22 GALLON TANK

Install red mold of body harness, PN 4362293, onto red stud of gauge/pump unit. Install yellow mold of harness, PN 4362293, onto black
stud of gauge/pump unit (Figure 3-A or 3-B).

Fuel system - Engine Vapor Lock|Page 362 > < Fuel system - Engine Vapor Lock|Page 360