dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Procedures|Page 2639 > < Procedures
Page 1
background image

Catalytic Converter: Removal and Replacement

Under Floor Catalytic Converter

UNDER FLOOR CATALYTIC CONVERTER

WARNING: THE NORMAL OPERATING TEMPERATURE OF THE EXHAUST SYSTEM IS VERY HIGH. THEREFORE, NEVER
WORK AROUND OR ATTEMPT TO SERVICE ANY PART OF THE EXHAUST SYSTEM UNTIL IT IS COOLED. SPECIAL CARE
SHOULD BE TAKEN WHEN WORKING NEAR THE CATALYTIC CONVERTER. THE TEMPERATURE OF THE CONVERTER RISES
TO A HIGH LEVEL AFTER A SHORT PERIOD OF ENGINE OPERATING TIME.

1.   Raise vehicle on hoist and apply penetrating oil to band clamp fastener of component being removed.

NOTE: Do not use petroleum-based lubricants when removing/installing muffler or exhaust pipe isolators as it may compromise the life
of the part. A suitable substitute is a mixture of liquid dish soap and water.

2.   Remove I-Pipe/Muffler assembly.
3.   Disconnect oxygen sensor electrical connectors.

NOTE: If spherical gasket is to be reused, mark orientation.

4.   Remove flange bolts (3), springs and spherical gasket.
5.   Remove under floor catalytic converter (4) from combination manifold/catalytic converter assembly (1).
6.   Clean ends of pipes to assure mating of all parts. Discard broken or worn isolators, rusted or overused clamps, supports, and attaching parts.

NOTE: When replacement is required on any component of the exhaust system, you must use original equipment parts (or their
equivalent).

Catalytic Converter - FWD

CATALYTIC CONVERTER - FWD

Procedures|Page 2639 > < Procedures