dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Condenser HVAC|Locations|Page 6896 > < Condenser HVAC|Locations|Page 6894
Page 1
background image

Condenser HVAC: Service and Repair

REMOVAL

WARNING:  REFER TO THE APPLICABLE WARNINGS AND CAUTIONS FOR THIS SYSTEM BEFORE PERFORMING THE
FOLLOWING OPERATION.

NOTE:  Before removing the condenser, note the location of each of the radiator and condenser air seals. These air seals are used to direct air through
the condenser and radiator. The air seals must be reinstalled in their proper locations in order for the air conditioning and engine cooling systems to
perform as designed.

1. Recover the refrigerant from the refrigerant system.

Fig.4 Radiator Sight Shield

2. Remove the two large screws that secure the front fascia and the outboard ends of the radiator sight shield to the radiator closure panel

crossmember.

3. Remove the five small screws that secure the front fascia grille inserts to the radiator sight shield.
4. Remove the radiator sight shield from the radiator closure panel crossmember.
5. Remove the two screws that secure the hood latch unit to the front of the radiator closure panel crossmember and move the latch out of the way

over the top of the crossmember. Mark the location of latch for reinstallation.

6. Disconnect the hoses from the transmission oil cooler fittings on the left side of the cooling module.
7. Remove the nut that secures the discharge line fitting to the condenser on the right side of the cooling module.
8. Disconnect the discharge line fitting from the condenser inlet port.
9. Remove the seal from the discharge line fitting and discard.

10. Install plugs in, or tape over the opened discharge line fitting and the condenser inlet port.
11. Remove the nut that secures the liquid line fitting to the condenser on the right side of the cooling module.
12. Disconnect the liquid line fitting from the condenser outlet port.
13. Remove the seal from the liquid line fitting and discard.
14. Install plugs in, or tape over the opened liquid line fitting and the condenser outlet port.

Condenser HVAC|Locations|Page 6896 > < Condenser HVAC|Locations|Page 6894