dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Turn Signal Switch - Momentary Loss of Ground|Page 369 > < Turn Signal Switch - Momentary Loss of Ground|Page 363
Page 1
background image

Turn Signal Switch: All Technical Service Bulletins
Turn Signal Switch - Momentary Loss of Ground

Models

1987-1/2 "S" With 2.5L or 3.0L Engine With Automatic Transmission and/or Speed Control

Subject

Intermittent DropOut of Speed Control or Torque Converter Lock-Up

Index

ELECTRICAL

Date

July 20, 1987

No..

08-18-87 (C21-08)

P-2596
SYMPTOM/CONDITION

Drop out of speed control and/or torque converter lock-up may occur with movement of the turn signal switch. Using the lane change function of the
switch may produce this condition.

DIAGNOSIS

1.

Remove the lower steering column cover and the hazard warning flasher.

2.

Turn on the hazard flasher switch.

FIGURE 1

3.

Using a digital volt/ohmmeter set on the 1K ohm scale, measure the resistance between the D4 (18wt) circuit and a good body ground. The D4
(18wt) circuit can be found in the 6-way wiring connector to the stop lamp switch (Figure 1). The reading should be 0.33 K ohms +/- 0.03 K ohms.

NOTE:

BEFORE MEASURING RESISTANCE WITH A DIGITAL VOLT/OHMMETER, A ZERO POINT MUST BE ESTABLISHED.
THIS CAN BE ACCOMPLISHED BY CROSSING THE LEADS OF THE OHMMETER AND NOTING THE READING ON
THE DIGITAL DISPLAY. THIS IS THE ZERO POINT. ALL READINGS SHOULD BE CALCULATED FROM THIS POINT.

4.

If the reading is outside the specified range, proceed with the following repair procedure.

Turn Signal Switch - Momentary Loss of Ground|Page 369 > < Turn Signal Switch - Momentary Loss of Ground|Page 363