dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

About Brake System Bleeding|Page 7029 > < About Brake System Bleeding|Page 7027
Page 5
background image

Fig. 4 BLEEDING MODULATOR ASSEMBLY PRIMARY ACCUMULATOR CIRCUIT

4 MODULATOR ASSEMBLY PRIMARY ACCUMULATOR CIRCUIT

8. Transfer clear bleed tube to primary accumulator bleed screw (Fig. 4). Then install bleed tube into a container partially filled with fresh clean 

brake fluid (Fig. 4).

9. Pump brake pedal several times, then apply a constant medium to heavy force on the brake pedal. Using the DRB Scan Tool, select the bleed

ABS hydraulic unit mode, and then select the primary circuit valves. (The RF and LR modulator assembly solenoids will tire for 5 seconds).

10. Open the modulator assembly primary accumulator circuit bleed screw (Fig. 4) at least one lull turn. This will ensure an adequate flow of brake

fluid from the primary accumulator circuit. Continue bleeding primary accumulator circuit until an air-free flow of brake fluid from bleed
screw is maintained or the brake pedal bottoms. If an air-free flew of brake fluid is not maintained before brake pedal bottoms, close bleed
screw and repeat steps 8 and 9 until an air free flow is maintained.

11. After an air-free flow of brake fluid is maintained from the primary accumulator bleed screw, close and lightly tighten bleed screw. Then

release pressure from brake pedal. Do not release force from brake pedal prior to closing and tightening bleed screw.

Note: For the next modulator assembly bleeding procedure, use of the DRB Scan Tool is not required. This step of the bleed procedure does
not require modulator solenoids to be operated for bleeding to be performed.

12. Pump brake pedal several times, then apply and hold a constant medium to heavy force on the brake pedal.

13. Again without firing modulator solenoids, open primary accumulator circuit bleed screw (Fig. 4) 1 full turn. This will ensure an adequate flow

of brake fluid from the primary accumulator circuit.

14. Bleed primary accumulator circuit until a clear, air-free flow of brake fluid is maintained from the accumulator bleed screw or the brake pedal

bottoms. If an air-free flow of brake fluid is not maintained from the bleed screw before the brake pedal bottoms. First, close bleed screw and
then repeat steps 11 and 12 of this bleeding procedure until an air-free flow is maintained.

15. After an air-free flow of brake fluid is maintained from the primary accumulator circuit bleed screw, close and lightly tighten bleed screw.

Then release force from brake pedal. Do not release force from brake pedal prior to closing and tightening bleeder screw.

16. After primary accumulator bleed screw is closed, remove bleed hose from bleed screw.

17. Torque primary accumulator bleed screw to 9 Nm (80 in. lbs.).