Page 3
background image

Unlocked 25 Way CAB Connector

5. Install the 25 way connector on the CAB using the following procedure. Position the 25 way connector in the socket of the CAB and carefully

push it down as far as possible. When connector is fully seated by hand into the CAB socket, push in the connector lock. This will pull the
connector into the socket of the CAB and lock it in the installed position.

NOTE:  The CAB wiring harness must be clipped to the HCU mounting bracket. This will ensure the wiring harness is properly routed and does
not contact the brake tubes or the body of the vehicle.

6. Clip the cab wiring harness to the HCU mounting bracket.

Brake Tube Routing Clips

7. Install the routing clips on the brake tubes.
8. Lower vehicle.
9. Connect negative cable back on negative post of the battery.

10. Bleed the base brakes and the ABS brakes hydraulic system.

See: Brake Bleeding/Service and Repair

11. Road test vehicle to ensure proper operation of the base and ABS systems.

Traction Control Indicator Lamp > < Hydraulic Control Assembly - Antilock Brakes|Removal|Page 5881