dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Air Outlets Replacement|Page 6463 > < Air Outlets Replacement|Page 6461
Page 1
background image

Air Duct: Service and Repair
Floor Distribution Ducts Replacement

REMOVAL 

1. Roll back the carpet on the front floor from under the instrument panel toward the rear of the vehicle. 

Fig.12 Floor Distribution Ducts

2. Lift the center floor distribution duct upward far enough to disengage its locator hole from the weld stud on the front floor panel.
3. Pull the floor distribution duct assembly rearward far enough to disengage the center floor distribution duct from the outlet on the bottom of the

heater-A/C housing unit.

4. Disassemble the right and/or left floor distribution ducts from the center floor distribution duct as required.

INSTALLATION

1. Assemble the right and/or left floor distribution ducts onto the center floor distribution duct as required.
2. Slide the floor distribution duct assembly under the instrument panel center stack far enough to engage the center floor distribution duct with the

outlet on the bottom of the heater-A/C housing unit.

3. Align the locator hole on the center floor distribution duct with the weld stud on the front floor panel.
4. Using hand pressure, push the locator hole of the center floor distribution duct down over the weld stud on the front floor panel.
5. Reinstall the carpet onto the front floor panel and under the instrument panel.

Air Outlets Replacement|Page 6463 > < Air Outlets Replacement|Page 6461