7. Position the front floor distribution duct (2) onto the air distribution housing (3).
8. Install the six screws (1) that secure the front floor distribution duct to the air distribution housing. Tighten the screws to 2 Nm (17 in. lbs.).
9. Install the blend door cam (9) onto the blend door lever (10) and the pivot shaft located on the driver side of the air distribution housing (8).
10. Install the floor door linkage (5) onto the floor door lever (4) and the pivot shaft on air distribution housing.
NOTE: Align the guide pin on the floor door linkage with the guides on the mode door cam during installation of the floor door linkage.
11. Install the mode door cam (6) onto the pivot shaft on air distribution housing.
12. Connect the defrost/demister door linkage rod (12) onto the defrost/demister door lever (11).
NOTE: Align the guide pin on the defrost/demister linkage with the guides on the mode door cam during installation of the defrost/demister
linkage.
13. Install the defrost/demister linkage (7) onto the pivot shaft on air distribution housing.
14. Connect the instrument panel door linkage rod (2) onto the instrument panel door lever (1).
NOTE: Align the guide pin on the instrument panel linkage with the guides on the mode door cam during installation of the instrument panel
linkage.
15. Install the instrument panel linkage (3) onto the pivot shaft on air distribution housing.