3. Install the screws (1) that secure the recirculation door actuator (2) to the air inlet housing (3). Tighten the screws to 2 Nm (17 in. lbs.).
4. Connect the HVAC wire harness connector (4) to the recirculation door actuator.
5. Install the glove box into the instrument panel See: Body and Frame/Interior Moulding / Trim/Glove Compartment/Service and Repair/Instrument
Panel Glove Box - Installation.
6. Reconnect the negative battery cable.
7. Initiate the Actuator Calibration function using a scan tool See: Service and Repair/HVAC Actuator Calibration Procedure.