dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Removal and Replacement|Page 4798 > < Removal and Replacement|Page 4796
Page 9
background image

16. Position the blend door actuator mounting bracket (6) and the mode door actuator mounting bracket (3) onto the driver side of the air distribution

housing (1).

17. Install the screws (5) that secure the mounting brackets to the air distribution housing. Tighten the screws to 2 Nm (17 in. lbs.).
18. Position the blend door actuator (7) onto the air distribution housing. If necessary, rotate the actuator slightly to align the splines on the actuator

output shaft with those on the blend door cam, See: Air Door/Air Door Actuator / Motor/Service and Repair/Blend Door Actuator - Installation.

19. Position the mode door actuator (4) onto the air distribution housing. If necessary, rotate the actuator slightly to align the splines on the actuator

output shaft with those on the mode door cam See: Air Door/Air Door Actuator / Motor/Service and Repair/Mode Door Actuator - Installation.

20. Install the screws (2) that secure the blend door actuator to the air distribution housing. Tighten the screws to 2 Nm (17 in. lbs.).
21. Position the mode door actuator mounting bracket (6) onto the driver side of the air distribution housing (1).
22. Install the screws that secure the blend door actuator mounting bracket to the air distribution housing. Tighten the screws to 2 Nm (17 in. lbs.).
23. Position the blend door actuator (7) onto the air distribution housing. If necessary, rotate the actuator slightly to align the splines on the actuator

output shaft with those on the blend-air door linkage See: Air Door/Air Door Actuator / Motor/Service and Repair/Blend Door Actuator -
Installation.

24. Install the screws (2) that secure the blend door and mode door actuators to the air distribution housing. Tighten the screws to 2 Nm (17 in. lbs.).
25. Install the air distribution housing onto the HVAC housing, See: Removal and Replacement/HVAC Housing - Installation.

Air Inlet Housing

HOUSING-AIR INLET

1. Position the recirculation-air door (4) into the air inlet housing (1).

CAUTION: Make sure that the recirculation-air door pivot shaft is properly seated in the pivot seats located on the air inlet housing.

2. Install the recirculation door actuator (3) onto the air inlet housing. If necessary, rotate the actuator slightly to align the splines on the actuator

output shaft with those on the recirculation door pivot shaft, See: Air Door/Air Door Actuator / Motor/Service and Repair/Recirculation Door
Actuator - Installation. 

3. Install the three screws (2) that secure the recirculation door actuator to the air inlet housing. Tighten the screws to 2 Nm (17 in. lbs.).
4. Install the air inlet housing onto the HVAC housing, See: Removal and Replacement/HVAC Housing - Installation.

Removal and Replacement|Page 4798 > < Removal and Replacement|Page 4796