dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Expansion Valve|Removal|Page 9321 > < Expansion Valve|Description|Page 9318
Page 1
background image

Expansion Valve: Service and Repair
Removal

REMOVAL

WARNING:  Refer to the applicable warnings and cautions for this system before performing the following operation. Failure to follow the
warnings and cautions could result in possible personal injury or death.

NOTE:  LHD model shown in illustrations. RHD model similar.

1. Disconnect and isolate the negative battery cable.

2. Recover the refrigerant from the refrigerant system.

3. Remove the bolt (5) that secures the refrigerant line mounting bracket (6) to the left front shock tower (4).

4. Remove the nut (9) that secures the refrigerant line tapping block (10) to the A/C expansion valve (1).

5. Disconnect the wire harness (3) from the A/C pressure transducer (2) to help allow access to the A/C expansion valve.

6. Disconnect the A/C suction line (7) and the A/C liquid line (8) from the A/C expansion valve and position the refrigerant lines out of the way.

7. Remove the dual plane seal from the suction and liquid line fittings and discard.

8. Install plugs in, or tape over the opened suction and liquid line fittings.

9. Remove the two bolts (1) that secure the A/C expansion valve (2) to the evaporator tube tapping block located within the foam seal (3).

10. Remove the A/C expansion valve from the evaporator tube tapping block and foam seal.

Expansion Valve|Removal|Page 9321 > < Expansion Valve|Description|Page 9318