21. Position the blend door actuator mounting bracket (6) and the mode door actuator mounting bracket (3) onto the driver side of the air distribution

housing (1).

22. Install the screws (5) that secure the mounting brackets to the air distribution housing. Tighten the screws to 2 Nm (17 in. lbs.).
23. Position the blend door actuator (7) onto the air distribution housing. If necessary, rotate the actuator slightly to align the splines on the actuator

output shaft with those on the blend door cam See: Air Door/Air Door Actuator / Motor/Service and Repair/Blend Door Actuator - Installation.

24. Position the mode door actuator (4) onto the air distribution housing. If necessary, rotate the actuator slightly to align the splines on the actuator

output shaft with those on the mode door cam See: Air Door/Air Door Actuator / Motor/Service and Repair/Mode Door Actuator - Installation.

25. Install the screws (2) that secure the blend door actuator to the air distribution housing. Tighten the screws to 2 Nm (17 in. lbs.).
26. Position the mode door actuator mounting bracket (6) onto the driver side of the air distribution housing (1).
27. Install the screws that secure the blend door actuator mounting bracket to the air distribution housing. Tighten the screws to 2 Nm (17 in. lbs.).
28. Position the blend door actuator (7) onto the air distribution housing. If necessary, rotate the actuator slightly to align the splines on the actuator

output shaft with those on the blend-air door linkage See: Air Door/Air Door Actuator / Motor/Service and Repair/Blend Door Actuator -
Installation.

29. Install the screws (2) that secure the blend door and mode door actuators to the air distribution housing. Tighten the screws to 2 Nm (17 in. lbs.).
30. Install the air distribution housing onto the HVAC housing See: Removal and Replacement/HVAC Housing - Installation.

Air Inlet Housing

HOUSING-AIR INLET

NOTE: The air inlet housing must be removed from HVAC housing and disassembled for service of the recirculation-air door.

NOTE: LHD model shown. RHD model similar.

1. Position the recirculation-air door (4) into the air inlet housing (1).

CAUTION: Make sure that the recirculation-air door pivot shaft is properly seated in the pivot seats located on the air inlet housing.

2. Install the recirculation door actuator (3) onto the air inlet housing. If necessary, rotate the actuator slightly to align the splines on the actuator

output shaft with those on the recirculation door pivot shaft See: Air Door/Air Door Actuator / Motor/Service and Repair/Recirculation Door