7. Install the strainer (1) in the inlet to torque converter lock-up control solenoid valve.
8. Position the sealing plate (3) onto the valve body (4).
9. Install the valve housing (2) onto the valve body (4) and sealing plate (3).
10. Install the shift plate Torx bolts (1). Tighten the bolts to 8 Nm (71 inch lbs.).
11. Install leaf spring (5).
12. Install the strainers (1, 2) for the modulating pressure and shift pressure control solenoid valves into the valve housing.