Colt L4-1795cc 1.8L SOHC (1994)
Camshaft Position Sensor: Testing and Inspection
Sensor Inspection
VOLTAGE TESTING PROCEDURE:
1. Connect a voltmeter between terminal 1 and 4 of the crank angle sensor connector.
Terminal 1: Sensor ground
Terminal 4: Camshaft (TDC) signal
2. Measure the output voltage of the terminals while cranking the engine.
Standard Approximate Value: 2.0 - 2.5v
3. When the voltage is abnormal, check the sensor power and ground circuits.