dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Condenser Fan Motor Relay, HVAC > < Compressor Clutch Relay|Locations|Page 3615
Page 1
background image

Condenser Fan Motor: Testing and Inspection

Fig. 41 - Condenser Fan Motor Terminal ID

1. Disconnect condenser fan motor electrical connector.
2. Connect 12 power supply to terminal 3 and ground terminal 1.
3. Condenser fan motor should run smoothly.
4. If motor does not operate as specified, replace fan motor.

Condenser Fan Motor Relay, HVAC > < Compressor Clutch Relay|Locations|Page 3615