dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Secondary Air Supply <--> [Air Injection]|Description and Operation|Page 1276 > < Voltage Signal|Description and Operation
Page 1
background image

Secondary Air Supply: Description and Operation

Fig. 4 Secondary air supply system. Models w/pulse air feeder (Typical)

MODELS W/PULSE AIR FEEDER
    On this system, Fig. 4, a Pulse Air Feeder (PAF) is used to supply secondary air to the exhaust system between the front and rear catalytic converters.
This secondary air combines with exhaust gasses to promote further oxidation in the rear catalytic converter.
    A main and sub-reed valve is incorporated in the Pulse Air Feeder. The main reed valve is actuated by a diaphragm which senses pressure pulsations
caused by piston movement in the No. 3 cylinder. The sub-reed valve is actuated by exhaust gas vacuum caused by pulsations in the exhaust system
between the front and rear catalytic converters.

Secondary Air Supply <--> [Air Injection]|Description and Operation|Page 1276 > < Voltage Signal|Description and Operation