dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Fluid - Differential > < Carrier Bearings|Adjustments
Page 2
background image

Fig. 23 Lock plate installation

7. Ensure backlash is within specifications, then install a suitable lock plate and torque attaching bolt to 11 to 16 ft. lbs..

Fluid - Differential > < Carrier Bearings|Adjustments