dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Cold Start Up Dieouts|Page 1400 > < Cold Start Up Dieouts
Page 2
background image

FIGURE 1

FIGURE 2

2.

Drain radiator coolant level enough to allow the removal of the T.I.D.C. valve. Remove and discard the CVS 3-port valve (this is the valve located
closest to the carburetor). Install T.I.D.C. 3-port valve, PN 4268716 (Figure 1).

3.

Remove and discard existing T.I.D.C. 3-port valve and replace it with CVS 5-port valve, PN 4307895 (Figure 1).

4.

Install engine vacuum harness, PN 4324480, connecting the 5-port and 3-port valves. Lay harness out as shown in Figure 1, connecting remaining
hoses to EGR valve, diverter valves, distributor, manifold vacuum tree, and carburetor (Figures 1 and 2).

NOTE:

ON THE CARBURETOR THERE ARE TWO HOSES, THE SHORTER ONE ATTACHES ON THE LOWER DRIVER'S
SIDE AND THE LONGER TO THE UPPER PASSENGER SIDE.

Cold Start Up Dieouts|Page 1400 > < Cold Start Up Dieouts