dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Fuel Fittings|Page 2027 > < Fuel Fittings|Page 2025
Page 3
background image

Fuel Line Quick Connect Fitting

REMOVAL

1. Disconnect negative battery cable.
2. Perform fuel pressure release procedure.
3. Push the quick connect fitting toward the fuel tube while depressing the plastic retainer. Then slightly twist the fitting and pull fitting off of fuel

tube. The retainer will remain on the fitting.

INSTALLATION

1. Using a clean lint free cloth, clean fuel tube nipple and retainer.
2. Using a clean motor oil, lightly lube nipple and retainer.

CAUTION:  Never install quick connect fitting if retainer ring is damaged or stuck in the release position.

Fuel Line Quick Connect Fitting

3. Push fitting over fuel tube until retainer seats and a click is heard. When the fitting is properly plastic retainer should be in the out position. 
4. Verify connection by pulling on the fuel tube. If fitting locks in place connection is secure.
5. Use the Automatic Shut Down (ASD) Fuel System Test on the DRB II to pressurize the fuel system and check for leaks.  

CAUTION:  The ASD relay and the fuel pump relay will remain energized for 7 minutes during this test unless the test is stopped or the ignition switch
is turned to the OFF position.

Fuel Fittings|Page 2027 > < Fuel Fittings|Page 2025