dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Cleaning and Inspection|Page 1647 > < Cleaning and Inspection
Page 1
background image

Catalytic Converter: Service and Repair
Removal and Installation

REMOVAL 

CAUTION:  When servicing or replacing exhaust system components, disconnect the oxygen sensor connector(s). Allowing the exhaust to hang by
the oxygen sensor wires will damage the harness and/or sensor.

1. Raise and support the vehicle.
2. Saturate the bolts and nuts with Mopar Rust Penetrant. Allow 5 minutes for penetration.

3. Remove the clamp holding the catalytic converter flange to the exhaust pipe(s).
4. Remove the clamp holding the catalytic converter flange to the muffler or extension pipe .
5. Remove the rear engine mount.
6. Remove the crossmember.
7. Remove the catalytic converter. You may have to loosen up other sections of the exhaust system.

INSTALLATION 

CAUTION:  When servicing or replacing exhaust system components, disconnect the oxygen sensor connector(s). Allowing the exhaust to hang by
the oxygen sensor wires will damage the harness and/or sensor.

1. Align and connect the catalytic converter flange to the exhaust pipe.

Cleaning and Inspection|Page 1647 > < Cleaning and Inspection