Dakota 2WD L4-2.5L VIN P (2001)
damaged.
6. Observe the multi-meter reading. The low-amperage IOD should not exceed thirty-five milliamperes (0.035 ampere). If the current draw
exceeds thirty-five milliamperes, isolate each circuit using the fuse and circuit breaker remove-and-replace process in Step 5. The multi-meter
reading will drop to within the acceptable limit when the source of the excessive current draw is disconnected. Repair this circuit as required;
whether a wiring short, incorrect switch adjustment, or a component failure is at fault.