dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Blower Motor Resistor > < Blower Motor Relay|Locations|Page 6245
Page 1
background image

Blower Motor Relay: Service and Repair

Fig 40  Power Distribution Center

1. Disconnect and isolate the battery negative cable.
2. Remove the cover from the Power Distribution Center (PDC).
3. Refer to the label on the PDC for blower motor relay identification and location.
4. Unplug the blower motor clutch relay from the PDC.
5. Install the blower motor relay by aligning the relay terminals with the cavities in the PDC and pushing the relay firmly into place.
6. Install the PDC cover.
7. Connect the battery negative cable.
8. Test the relay operation.