Dakota 2WD V6-3.9L VIN X (1997)
Blower Motor Relay: Service and Repair
Fig 40 Power Distribution Center
1. Disconnect and isolate the battery negative cable.
2. Remove the cover from the Power Distribution Center (PDC).
3. Refer to the label on the PDC for blower motor relay identification and location.
4. Unplug the blower motor clutch relay from the PDC.
5. Install the blower motor relay by aligning the relay terminals with the cavities in the PDC and pushing the relay firmly into place.
6. Install the PDC cover.
7. Connect the battery negative cable.