5. Remove the three screws that secure the ACM mounting bracket to the floor pan transmission tunnel.
6. Remove the ACM and mounting bracket as a unit.
7. When installing the ACM, position the unit with the arrow on the ACM housing pointing forward.
8. Attach the ACM to the floor pan transmission tunnel with the four mounting screws. Tighten the mounting screws to 11.8 N.m (105 in. lbs.).
9. Plug in the wire harness connector to the ACM. Be certain that the connector latches are fully engaged and that the connector locks are pushed in.

10. Reverse the remaining removal procedures to complete the installation.