dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Torque Converter Clutch, A/T > < Torque Converter|Specifications|Page 4541
Page 1
background image

Torque Converter Check Valve: Service and Repair

The converter drainback check valve is located in the cooler outlet (pressure) line near the radiator lower tank. The valve prevents fluid drainback when
the vehicle is parked for lengthy periods. The valve check ball is spring loaded and has an opening pressure of approximately 2 psi.

The valve is serviced as an assembly; it is not repairable. Do not clean the valve if restricted, or contaminated by sludge, or debris. If the valve fails, or if
a transmission malfunction occurs that generates sludge and or clutch particles and metal shavings, the valve must be replaced.

The valve must be removed whenever the cooler and lines are reverse flushed. The valve can be flow tested when necessary. The procedure is exactly the
same as for flow testing a cooler.

If the valve is restricted, installed backwards, or in the wrong line, it will cause an overheating condition and possible transmission failure.

CAUTION:  The drainback valve is a one-way flow device. It must be properly oriented in terms of flow direction for the cooler to function properly.
The valve must be installed in the pressure line. Otherwise flow will be blocked and would cause an overheating condition and eventual transmission
failure.

Torque Converter Clutch, A/T > < Torque Converter|Specifications|Page 4541