Blower Motor Housing Cover Remove/Install

17. Remove the six screws that secure the blower motor housing cover to the heater-A/C housing.
18. Remove the blower motor housing cover from the heater-A/C housing.

ASSEMBLY

Blower Motor Housing Cover Sealant

1. Before installing the blower motor housing cover, be certain that the cover sealant is in place and in good condition.
2. Position the blower motor housing cover to the heater-A/C housing.
3. Install the six screws that secure the blower motor housing cover to the heater-A/C housing. Tighten the screws to 2.2 Nm (20 in. lbs.).
4. If the vehicle is so equipped, reinstall the recirculation air door actuator. See Mode Door Vacuum Actuators in the Removal and Installation for

the procedures.

Removal and Replacement|Page 5435 > < Removal and Replacement|Page 5433