6. Position the panel door actuator (1) onto the driver side end of the HVAC housing (2). If necessary, rotate the actuator slightly to align the splines
on the actuator output shaft (3) with those on the panel door pivot shaft (4).
7. Install the three screws (1) that secure the panel door actuator (2) to the HVAC housing (3). Tighten the screws to 2 Nm (17 in. lbs.).
8. Connect the HVAC wire harness connector (4) to the panel door actuator.
9. Reconnect the negative battery cable.
10. Initiate the Actuator Calibration function using a scan tool.