dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Refrigerant|Service and Repair > < A/C Refrigerant|Page 1503
Page 1
background image

Refrigerant: Testing and Inspection

REFRIGERANT SYSTEM LEAKS

WARNING: R-134a service equipment or vehicle A/C system should not be pressure tested or leak tested with compressed air. Mixture of air
and R-134a can be combustible at elevated pressures. These mixtures are potentially dangerous and may result in fire or explosion causing
property damage, personal injury or death.
Avoid breathing A/C refrigerant and lubricant vapor or mist. Exposure may irritate eyes, nose and throat. Use only approved service
equipment meeting SAE requirements to discharge R-134a system. If accidental system discharge occurs, ventilate work area before resuming
service.

If the refrigerant system is empty or low in refrigerant charge, a leak at any line fitting or component seal is likely. A review of the fittings, lines and
components for oily residue is an indication of the leak location. If the A/C liquid line pressure is found to be less than 345 kPa (50 psi), proceed to the
System Empty procedure below. If liquid line pressure is found to be greater than 345 kPa (50 psi), proceed to the System Low procedure. If the A/C
system is not cooling properly, determine if the refrigerant system is fully charged with R-134a. This is accomplished by completely evacuating and
recharging the A/C system. To detect a leak in the refrigerant system, perform one of the following procedures as indicated by the symptoms.

SYSTEM EMPTY

1. Evacuate the refrigerant system to the lowest degree of vacuum possible (approximately 28 in Hg.) See: Heating and Air Conditioning/Service and

Repair/Refrigerant System Evacuate. Determine if the system holds a vacuum for 15 minutes. If vacuum is held, a leak is probably not present. If
system will not maintain vacuum level, proceed to STEP 2.

2. Prepare and dispense 0.284 kilograms (10 ounces) of R-134a refrigerant into the evacuated refrigerant system See: Heating and Air

Conditioning/Service and Repair/Refrigerant System Charge and proceed to STEP 1 of the System Low procedure.

SYSTEM LOW

3. Position the vehicle in a wind free work area. This will aid in detecting small leaks.
4. Operate the heating-A/C system with the engine at idle under the following conditions for at least five minutes.

-

Doors or windows open

-

Transmission in Park or Neutral with the parking brake set (depending on application)

-

A/C-heater controls set to outside air, full cool, panel mode, high blower and with A/C compressor engaged

CAUTION: A leak detector only designed for R-12 refrigerant will not detect leaks in a R-134a refrigerant system.

5. Shut the vehicle Off and wait 2-7 minutes. Then use an electronic leak detector that is designed to detect R-134a refrigerant and search for leaks.

Fittings, lines or components that appear to be oily usually indicate a refrigerant leak. To inspect the A/C evaporator for leaks, insert the leak
detector probe into the drain tube opening or an air outlet. A dye for R-134a is available to aid in leak detection. Use only DaimlerChrysler
approved refrigerant dye.

Refrigerant|Service and Repair > < A/C Refrigerant|Page 1503