dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Hose/Line HVAC > < Heater Core|Installation|Page 6845
Page 1
background image

High Pressure Safety Valve HVAC: Description and Operation
A/C Compressor - Operation

HIGH PRESSURE RELIEF VALVE

The high pressure relief valve vents refrigerant from the A/C system when a discharge pressure of 3445 to 4135 kPa (500 to 600 psi) or above is
reached. The high pressure relief valve closes with a minimum discharge pressure of 2756 kPa (400 psi) is reached.

The high pressure relief valve vents only enough refrigerant to reduce the A/C system pressure, and then re-seats itself. The majority of the refrigerant is
conserved in the A/C system. If the high pressure relief valve vents refrigerant, it does not mean the valve is inoperative.

The high pressure relief valve is factory-calibrated and cannot be adjusted or repaired, and must not be removed or otherwise disturbed. The valve is
only serviced as a part of the A/C compressor.

Hose/Line HVAC > < Heater Core|Installation|Page 6845