dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Cigarette Lighter > < Charge Lamp/Indicator|Description
Page 1
background image

Charge Lamp/Indicator: Description and Operation
Operation

OPERATION

The charging indicator gives an indication to the vehicle operator when the electrical system voltage is too low or too high. This indicator is controlled
by a transistor on the instrument cluster circuit board based upon cluster programming and electronic messages received by the cluster from the
Powertrain Control Module (PCM) over the Controller Area Network (CAN) data bus.

The charging indicator Light Emitting Diode (LED) is completely controlled by the instrument cluster logic circuit, and that logic will only allow this
indicator to operate when the instrument cluster receives a battery current input on the fused ignition switch output (run-start) circuit. Therefore, the LED
will always be OFF when the ignition switch is in any position except ON or START. The LED only illuminates when it is provided a path to ground by
the instrument cluster transistor. The instrument cluster will turn ON the charging indicator for the following reasons:

-

Bulb Test  - Each time the ignition switch is turned to the ON position the charging indicator is illuminated by the instrument cluster for about two
seconds as a bulb test.

-

Voltage Low Message  - Each time the cluster receives an electronic system voltage  message from the PCM indicating the voltage is low (less
than about 11.5 volts is a charge fail condition), the charging indicator will be illuminated. The indicator remains illuminated until the cluster
receives a message from the PCM indicating the voltage is normal (greater than about 12.0 volts, but less than 16.0 volts), or until the ignition
switch is turned to the OFF position, whichever occurs first.

-

Voltage High Message  - Each time the cluster receives an electronic system voltage  message from the PCM indicating the voltage is high
(greater than about 16.0 volts), the charging indicator will be illuminated. The indicator remains illuminated until the cluster receives a message
from the PCM indicating the voltage is normal (less than about 15.5 volts, but greater than 11.5 volts), or until the ignition switch is turned to the
OFF position, whichever occurs first.

-

Actuator Test  - Each time the cluster is put through the actuator test, the charging indicator will be turned ON, then OFF again during the bulb
check portion of the test to confirm the functionality of the LED and the cluster control circuitry.

The PCM continually monitors the electrical system voltage to control the generator output. The PCM then sends the proper messages to the
ElectroMechanical Instrument Cluster (EMIC) (also known as the Cab Compartment Node/CCN). If the instrument cluster turns ON the charging
indicator due to a charge fail or voltage high condition, it may indicate that the charging system requires service. For further diagnosis of the charging
indicator or the instrument cluster circuitry that controls the indicator, Refer to appropriate testing.  See: Instrument Cluster / Carrier/Testing and
Inspection

For proper diagnosis of the charging system, the PCM, the EMIC, the CAN data bus or the electronic communication related to charging indicator
operation a diagnostic scan tool is required.

Cigarette Lighter > < Charge Lamp/Indicator|Description