dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Evaporative Emissions System > < Catalytic Converter|Removal|Page 3496
Page 1
background image

Catalytic Converter: Service and Repair
Installation

3.7L/4.7L ENGINE

CAUTION: When servicing or replacing exhaust system components, disconnect the oxygen sensor connector(s). Allowing the exhaust to hang
by the oxygen sensor wires will damage the harness and/or sensor.

NOTE: The band clamps are not reusable. After removal, they must be replaced with new one.

1. Make sure the catalytic converter pipe is free of burrs.
2. Insert the catalytic converter into the exhaust pipe.
3. Make sure the alignment tang is fully seated in the alignment slot.
4. If other sections of the exhaust system where loosened in removal, refer to that information for the tightening procedures.
5. At the catalytic converter-to-extension pipe connection, install new clamp and nuts. Tighten the clamp nuts to 61 Nm (45 ft. lbs.) torque.
6. Lower the vehicle.
7. Start the engine, inspect for exhaust leaks. Repair exhaust leaks as necessary.
8. Check the exhaust system for contact with the body panels. Make the necessary adjustments, if necessary.

Evaporative Emissions System > < Catalytic Converter|Removal|Page 3496