NOTE:  If the seal for the panel/defrost outlet is deformed or damaged, the seal must be replaced.

16. Install the foam seal (1) onto the panel/defrost outlet (2) located on the top of the HVAC housing (3).

17. Position the air inlet housing (2) onto the top of the HVAC housing (3).

NOTE:  If the foam seal on the air inlet housing is deformed or damaged, the seal must be replaced.

18. Install the four screws (1) that secure the air inlet housing to the top of the HVAC housing. Tighten the screws to 2 Nm (17 in. lbs.).

19. Position the blower motor (4) into the HVAC housing (6).

20. Install the three screws (5) that secure the blower motor to the HVAC housing. Tighten the screws to 2 Nm (17 in. lbs.).