Page 3
background image

Fig. 48 Oxygen Sensor Locations

WARNING:  THE EXHAUST MANIFOLD, EXHAUST PIPES AND CATALYTIC CONVERTER BECOME VERY HOT DURING
ENGINE OPERATION. ALLOW ENGINE TO COOL BEFORE REMOVING OXYGEN SENSOR.

1. Raise and support the vehicle.
2. Disconnect the wire connector from the O2S sensor.

CAUTION:  When disconnecting the sensor electrical connector, do not pull directly on wire going into sensor.

3. Remove the O2S sensor with an oxygen sensor removal and installation tool.

INSTALLATION

Threads of new oxygen sensors are factory coated with anti-seize compound to aid in removal. DO NOT add any additional anti-seize compound to
the threads of a new oxygen sensor.
1. Install the O2S sensor. Tighten to 30 Nm (22 ft. Lbs.)  torque.
2. Connect the O2S sensor wire connector.
3. Lower the vehicle.