dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

42RE (A-500) 4 Speed|Page 3649 > < 42RE (A-500) 4 Speed|Page 3647
Page 6
background image

Torque multiplication is achieved by locking the stator's over-running clutch to its shaft (Fig. 113). Under stall conditions (the turbine is stationary),
the oil leaving the turbine blades strikes the face of the stator blades and tries to rotate them in a counterclockwise direction. When this happens the
over-running clutch of the stator locks and holds the stator from rotating. With the stator locked, the oil strikes the stator blades and is redirected into a
"helping" direction before it enters the impeller. This circulation of oil from impeller to turbine, turbine to stator, and stator to impeller, can produce a
maximum torque multiplication of about 2.4:1. As the turbine begins to match the speed of the impeller, the fluid that was hitting the stator in such as
way as to cause it to lock-up is no longer doing so. In this condition of operation, the stator begins to free wheel and the converter acts as a fluid
coupling.

TORQUE CONVERTER CLUTCH (TCC)

In a standard torque converter, the impeller and turbine are rotating at about the same speed and the stator is freewheeling, providing no torque
multiplication. By applying the turbine's piston and friction material to the front cover, a total converter engagement can be obtained. The result of this
engagement is a direct 1:1 mechanical link between the engine and the transmission. The clutch can be engaged in second, third, and fourth gear
ranges depending on overdrive control switch position. If the overdrive control switch is in the normal ON position, the clutch will engage after the
shift to fourth gear, and above approximately 72 km/in (45 mph). If the control switch is in the OFF position, the clutch will engage after the shift to
third gear, at approximately 56 km/in (35 mph) at light throttle. The TCM controls the torque converter by way of internal logic software. The
programming of the soft-ware provides the TCM with control over the L/R-CC Solenoid. There are four output logic states that can be applied as
follows:
-

No EMCC

-

Partial EMCC

-

Full EMCC

-

Gradual-to-no EMCC

NO EMCC

Under No EMCC conditions, the L/R Solenoid is OFF. There are several conditions that can result in NO EMCC operations. No EMCC can be
initiated due to a fault in the transmission or because the TCM does not see the need for EMCC under current driving conditions.

PARTIAL EMCC

Partial EMCC operation modulates the L/R Solenoid (duty cycle) to obtain partial torque converter clutch application. Partial EMCC operation is
maintained until Full EMCC is called for and actuated. During Partial EMCC some slip does occur. Partial. EMCC will usually occur at low speeds,
low load and light throttle situations.

FULL EMCC

During Full EMCC operation, the TCM increases the L/R Solenoid duty cycle to full ON after Partial EMCC control brings the engine speed within
the desired slip range of transmission input speed relative to engine rpm.

GRADUAL-TO-NO EMCC

This operation is to soften the change from Full or Partial EMCC to No EMCC. This is done at mid-throttle by decreasing the L/R Solenoid duty
cycle.

42RE (A-500) 4 Speed|Page 3649 > < 42RE (A-500) 4 Speed|Page 3647