Radiator Cooling Fan Motor: Testing and Inspection

ELECTRIC COOLING FAN 

The Powertrain Control Module (PCM) will set a Diagnostic Trouble Code (DTC) in memory if it detects a problem in the electric cooling fan , relay
or circuit. 
The DTC can also be accessed through the DRB scan tool. 

RADIATOR FAN MOTOR INOPERATIVE 

Equipment Required:
^

DRB Scan Tool

^

Volt/Ohm meter

^

Wiring Diagrams

Test Procedure:

1. Inspect 10A fuse in junction block and 40A maxi fuse in PDC.
2. Remove Cooling Fan Relay from the PDC and make the following checks at the relay connector:

^

Apply 12 volts (using a fused 14-gauge wire) to circuit C25 (relay terminal 87). If fan does not come on, check for open in circuit C25 or Z1.